Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BackgroundVeno-venous extracorporeal membrane oxygenation (V-V ECMO) is a lifesaving support modality for severe respiratory failure, but its resource-intensive nature led to significant controversy surrounding its use during the COVID-19 pandemic. We report the performance of several ECMO mortality prediction and severity of illness scores at discriminating survival in a large COVID-19 V-V ECMO cohort.MethodsWe validated ECMOnet, PRESET (PREdiction of Survival on ECMO Therapy-Score), Roch, SOFA (Sequential Organ Failure Assessment), APACHE II (acute physiology and chronic health evaluation), 4C (Coronavirus Clinical Characterisation Consortium), and CURB-65 (Confusion, Urea nitrogen, Respiratory Rate, Blood Pressure, age >65 years) scores on the ISARIC (International Severe Acute Respiratory and emerging Infection Consortium) database. We report discrimination via Area Under the Receiver Operative Curve (AUROC) and Area under the Precision Recall Curve (AURPC) and calibration via Brier score.ResultsWe included 1147 patients and scores were calculated on patients with sufficient variables. ECMO mortality scores had AUROC (0.58-0.62), AUPRC (0.62-0.74), and Brier score (0.286-0.303). Roch score had the highest accuracy (AUROC 0.62), precision (AUPRC 0.74) yet worst calibration (Brier score of 0.3) despite being calculated on the fewest patients (144). Severity of illness scores had AUROC (0.52-0.57), AURPC (0.59-0.64), and Brier Score (0.265-0.471). APACHE II had the highest accuracy (AUROC 0.58), precision (AUPRC 0.64), and best calibration (Brier score 0.26).ConclusionWithin a large international multicenter COVID-19 cohort, the evaluated ECMO mortality prediction and severity of illness scores demonstrated inconsistent discrimination and calibration highlighting the need for better clinically applicable decision support tools.

Original publication

DOI

10.1111/aor.14542

Type

Journal

Artificial organs

Publication Date

04/2023

Addresses

Division of Pediatric Critical Care, Department of Pediatrics, Washington University in St. Louis, St. Louis, Missouri, USA.

Keywords

ISARIC Clinical Characterisation Group