We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Rationale: Conventional parameters to determine the success of spontaneous breathing trials (SBTs) may fail to detect impending respiratory distress. Objectives: To assess whether SBT-induced changes in respiratory system compliance, inspiratory effort, and respiratory drive measured as occlusion pressure during the first 100 milliseconds (P0.1), all assessed noninvasively through airway occlusions, are associated with extubation outcomes. Methods: We conducted a multicenter study on patients at high risk of extubation failure who successfully passed a 30-minute SBT on the basis of conventional parameters. The SBT was reproduced using a specific ventilator immediately before extubation to continuously monitor respiratory system compliance, inspiratory effort, and P0.1. Extubation failure was defined as reintubation within 72 hours. Measurements and Main Results: Forty-six (19%) of 238 extubated patients required reintubation. No differences in Vt or respiratory rate were observed between successfully extubated and reintubated patients at any time. In the success group, inspiratory effort and normalized compliance (i.e., scaled to predicted body weight) remained unchanged throughout the SBT. In the failure group, normalized compliance declined (1.0 [0.8-1.2] to 0.7 [0.6-0.9] ml/cm H2O/kg; P < 0.001), whereas inspiratory effort increased (12 [10-15] to 18 [15-20] cm H2O; P < 0.001) during the SBT. P0.1 increased in both groups but more markedly in reintubated patients (2 [1.5-2.4] to 3.2 [2.9-3.5] cm H2O; P < 0.001). SBT-induced normalized compliance reduction less than or equal to -0.2 ml/cm H2O/kg (less than or equal to -0.1; less than or equal to -0.2) and inspiratory effort increase >2 cm H2O (>1, >3) were the most accurate predictors of extubation failure (area under the curve, 0.90 [0.84-0.93]; sensitivity, 80%; specificity, 83%; area under the curve, 0.94 [0.90-0.97]; sensitivity, 89%; specificity, 93%, respectively). Conclusions: In high-risk patients, SBT-induced declines in respiratory system compliance and increases in inspiratory effort are associated with extubation failure. Clinical trial registered with www.clinicaltrials.gov (NCT05295186).

More information Original publication

DOI

10.1164/rccm.202503-0544oc

Type

Journal article

Publication Date

2025-12-01T00:00:00+00:00

Volume

211

Pages

2340 - 2351

Total pages

11

Addresses

D, e, p, a, r, t, m, e, n, t, , o, f, , P, r, e, c, i, s, i, o, n, -, R, e, g, e, n, e, r, a, t, i, v, e, , M, e, d, i, c, i, n, e, , a, n, d, , J, o, n, i, c, , A, r, e, a, ,, , S, e, c, t, i, o, n, , o, f, , A, n, e, s, t, h, e, s, i, o, l, o, g, y, ,, , U, n, i, v, e, r, s, i, t, y, , o, f, , B, a, r, i, , ", A, l, d, o, , M, o, r, o, ,, ", , B, a, r, i, ,, , I, t, a, l, y, .

Keywords

Humans, Respiratory Insufficiency, Treatment Failure, Ventilator Weaning, Respiratory Mechanics, Inhalation, Aged, Middle Aged, Female, Male, Airway Extubation