We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Recently, transmission Raman spectroscopy has been shown to be a valuable tool in the volumetric quantification of pharmaceutical formulations. In this work a Monte Carlo simulation and experimental study are performed to elucidate the dependence of the Raman signal on depth from the viewpoint of probing pharmaceutical tablets and powders in this experimental configuration. The transmission Raman signal is shown to exhibit a moderate bias toward the center of the tablets and this can be considerably reduced by using a recently developed Raman signal-enhancing concept, the "photon diode." The enhancing element not only reduces the bias but also increases the overall Raman signal intensity and consequently improves the signal-to-noise ratio of the measured spectrum. Overall, its implementation with appropriately chosen reflectivity results in a more uniform volumetric sampling across the half of the tablet where the photon diode is used (or across the tablet's entire depth if two photon diodes are used on each side of tablet) and enhanced overall sensitivity. These findings are substantiated experimentally on a segmented tablet by inserting a poly(ethelyne terephthalate) (PET) film doped with TiO(2) at different depths and monitoring its contribution to the overall transmission Raman signal from the segmented tablet. The numerical simulations also indicate considerable sensitivity of the overall Raman signal to the absorption of the sample, which is in line with large migration distances traversed by photons in these measurements. The presence of sample absorption was shown numerically to reduce the signal enhancement effect while the overall depth-dependence profile remained broadly unchanged. The absorption was also shown to produce a depth profile with the photon diode similar to that without it, although with a reduced absolute intensity of Raman signals and diminished enhancement effect.

Original publication

DOI

10.1366/11-06259

Type

Journal

Applied spectroscopy

Publication Date

07/2011

Volume

65

Pages

724 - 733

Addresses

Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, Harwell Oxford, Didcot, UK. Pavel.Matousek@stfc.ac.uk

Keywords

Tablets, Spectrum Analysis, Raman, Monte Carlo Method, Computer Simulation