We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

ObjectivesClinical observation suggests that early acute respiratory distress syndrome induced by the severe acute respiratory syndrome coronavirus 2 may be "atypical" due to a discrepancy between a relatively unaffected static respiratory system compliance and a significant hypoxemia. This would imply an "atypical" response to the positive end-expiratory pressure.DesignSingle-center, unblinded, crossover study.SettingICU of Bari Policlinico Academic Hospital (Italy), dedicated to care patients with confirmed diagnosis of novel coronavirus disease 2019.PatientsEight patients with early severe acute respiratory syndrome coronavirus 2 acute respiratory distress syndrome and static respiratory compliance higher than or equal to 50 mL/cm H2O.InterventionsWe compared a "lower" and a "higher" positive end-expiratory pressure approach, respectively, according to the intervention arms of the acute respiratory distress syndrome network and the positive end-expiratory pressure setting in adults with acute respiratory distress syndrome studies.Measurements and main resultsPatients were ventilated with the acute respiratory distress syndrome network and, subsequently, with the ExPress protocol. After 1 hour of ventilation, for each protocol, we recorded arterial blood gas, respiratory mechanics, alveolar recruitment, and hemodynamic variables. Comparisons were performed with analysis of variance for repeated measures or Friedman test as appropriate. Positive end-expiratory pressure was increased from 9 ± 3.5 to 17.7 ± 1.7 cm H2O (p < 0.01). Alveolar recruitment was 450 ± 111 mL. Static respiratory system compliance decreased from 58.3 ± 7.6 mL/cm H2O to 47.4 ± 14.5 mL/cm H2O (p = 0.018) and the "stress index" increased from 0.97 ± 0.03 to 1.22 ± 0.07 (p < 0.001). The PaO2/FIO2 ratio increased from 131 ± 22 to 207 ± 41 (p < 0.001), and the PaCO2 increased from 45.9 ± 12.7 to 49.8 ± 13.2 mm Hg (p < 0.001). The cardiac index went from 3.6 ± 0.4 to 2.9 ± 0.6 L/min/m (p = 0.01).ConclusionsOur data suggest that the "higher" positive end-expiratory pressure approach in patients with severe acute respiratory syndrome coronavirus 2 acute respiratory distress syndrome and high compliance improves oxygenation and lung aeration but may result in alveolar hyperinflation and hemodynamic alterations.

Original publication

DOI

10.1097/ccm.0000000000004640

Type

Journal

Critical care medicine

Publication Date

12/2020

Volume

48

Pages

e1332 - e1336

Addresses

Dipartimento dell'Emergenza e Trapianti d'Organo (DETO), Sezione di Anestesiologia e Rianimazione, Università degli Studi di Bari "Aldo Moro," Bari, Italy.

Keywords

Humans, Blood Gas Analysis, Positive-Pressure Respiration, Cross-Over Studies, Respiratory Mechanics, Adult, Aged, Aged, 80 and over, Middle Aged, Female, Male, Respiratory Distress Syndrome, COVID-19, SARS-CoV-2