We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

AimTo develop limited sampling strategy (LSS) for estimation of C(max) and AUC(0-t) and assessing the bioequivalence of two pioglitazone hydrochloride (PGT) preparations.MethodsHealthy subjects (n = 20), enrolled in a bioequivalence study, were received 30 mg PGT po of reference or test formulation. The plasma concentration of PGT was determined by the validated HPLC method. A multiple linear regression analysis of the Cmax and AUC(0-t) against the PGT concentration for the reference formulation was carried out to develop LSS models to estimate these parameters. The models were internally validated by the Jackknife method and externally validated using simulated sets generated by Monte Carlo method. The best model was employed to assess bioequivalence of the two PGT formulations.ResultsThe linear relationship between pharmacokinetics parameters and single concentration point was poor. Several models for these parameters estimation met the predefined criteria (r2 > 0.9). The Jackknife validation procedure revealed that LSS models based on two sampling times (C1, C2.5 and C1.5, C2.5 for C(max); C1.5, C9 and C2.5, C9 for AUC(0-t) predict accurately. Mean prediction errors (MPE) were less than 3%, and mean absolute prediction error (MAE) were less than 9%. The prediction error (PE) beyond 20% was less than 5% of total samples. Model external validation by Monte Carlo simulated data indicated that the most informative sampling combinations were C1.5, C2.5 for C(max), and C1.5, C9 for AUC(0-t), respectively. MPE and MAE of the proposed models were less than 5% , and 9% respectively. The PE beyond 20% was less than 5% of the total. Bioequivalence assessment of the two PGT formulations, based on the best LSS models, provided results similar to those obtained using all the observed concentration-time data points, and indicated that the two PGT formulations were bioequivalent.ConclusionThe LSS method for bioequivalence assessment of PGT formulations was established and proved to be applicable and accurate. Thus, it could be considered appropriate for PGT bioequivalence study with inexpensive cost of sampling acquisition and analysis. Key words: pioglitazone hydrochloride; limited sampling strategy; Monte Carlo simulation; bioequivalence

Type

Journal

Yao xue xue bao = Acta pharmaceutica Sinica

Publication Date

09/2006

Volume

41

Pages

893 - 898

Addresses

Children' s Hospital, Fudan University, Shanghai 200032, China.

Keywords

Humans, Thiazolidinediones, Hypoglycemic Agents, Chromatography, High Pressure Liquid, Administration, Oral, Area Under Curve, Monte Carlo Method, Sample Size, Therapeutic Equivalency, Models, Biological, Adult, Male, Pioglitazone